QHY268C on FSQ85

Connecting QHY268C/OAG To FSQ85 (none reduced) With An All-Threaded Connection

Introduction

I've bought a QHY268C colour CMOS camera and a QHYOAG-M as discussed in my post here.  As I explain in that post, my intention is to connect this up to my Takahashi FSQ85 "BabyQ" and make it an extensible system so that with easy and minor changes I can also connect the camera/OAG assembly to my Williams Optics Redcat 51, Samyang 135mm lens and maybe other optical systems (although its primary use will be on the FSQ85).  I also explain in that post how to configure the QHY268C and the OAG assembly such that both camera and guide camera can both reach focus simultaneously by "padding" out the camera side of the OAG with about 13mm of spacers between the OAG and the camera in order to get both cameras to simultaneously focus.

I now needed to determine a way  to mount the OAG-QHY268C assembly via a threaded method to the FSQ (and Redcat).  I do not like the 2" barrel compression method of attaching expensive camera assemblies to telescopes for imaging purposes (fine for visual).  Your mileage may vary but in my opinion they are risky at best and can introduce tilt into the optical train.  I have had them fall out before (fortunately caught by the USB and power cables).  So in the context of this discussion it has to be a threaded method of attachment and furthermore this method must allow for the insertion of a 2" filter.  I need to use a 2" IDAS light pollution filter in the imaging train because of my backyard Bortle 5 suburban skies so I needed to figure this out. Furthermore, this filter must be easily and readily changeable - possibly when set up at night - since I have plans to use this camera with a narrowband filter such as the Optolong L-Extreme.

Bear in mind when considering filters that even though the QHY268C is a OSC camera, there is nothing to prevent you from using a filter wheel between the camera and the OAG.  This FW can be populated with an LDAS LP filter and an L-Extreme (and others).  It would also serve to "pad" the camera back from the OAG to achieve the objectives I outlined in my previous post. However, for now I have exhausted the budget and do not wish to use a filter wheel.  So I need to install a filter drawer into the imaging train, and I needed to figure out how.

NOTE:  This mechanism I describe applies to the Takahashi FSQ85.  I can't comment if it works on other Takahashi telescopes. One tends not to have multiple Takahashi FSQ telescopes ($$$$$$$) ! 🤣

SECOND NOTE: The method I describe is the telescope at native focal length without the FSQ 0.73 reducer.  I no longer use the focal reducer with this telescope and sold it.


FSQQHY268C threaded connection
Labelled Adapter for Threaded fit to FSQ85

The Crazy And Expensive World Of Takahashi Adapters.

As owners of Takahashi refractors will be very aware, if you want an all-threaded method of connection then several costly adapters are needed to get the telescope to focus with a camera.   The focal point of the telescope is a quite a distance from the rear of the focuser housing - about 200mm or so in my example. Therefore, to get the camera to focus this space must be made up by racking out the focuser and also with adapters.  The stock focuser with the FSQ85 does indeed rack out a long way, but not enough to make up for the 200mm distance to the focus point.  It is never a good idea to have the focuser racked out too far because doing so can introduce a slight flop and sag in the focuser, a bad thing when imaging since the imaging sensor in the camera will not then be orthogonal to the imaging circle.  With that in mind, the adapters I choose are such that the focuser is 80% into the focuser housing to minimise any flop risk.

As an aside, my FSQ85 example is from 2012 and has a good focuser but I have heard reports that the focuser on more recent examples are not as good and cause issues in the corners of the image.  Indeed, I have heard where people have upgraded to a Starlight Instruments focuser at a cost of £700, rather a lot to have to pay on top of the already eye-watering cost of Takahashi FSQ ownership! 😱 


FSQ_QHY back focus
Distance to the focal point on FSQ85

Please refer to the top picture.  The first adapters I have used are two Takahashi TKA31581 Vari-Ring Spacers, each of which adds 17mm to the imaging train.  This has a 72mm male telescope side thread and ends in a 72mm female camera side.    These adapters are not too expensive, about £21 each in the UK.  So with two of them in series I am adding 34mm to the imaging train.  You can add as many of these as you wish to get the back focus for a particular situation, hence the term "vari" in the adapter name.

As an aside, Instead of using the two adapters I used, you could instead use the Takahashi Auxiliary Extender (TKA23250) which extends the M72 female threads at the end of the focuser tube and presents a female M72 thread. This adds 50mm to the imaging train.

The next part in the imaging train is the CA35 TSA102 (TKA23201) adapter whose purpose is to drop the Takahashi 72mm thread from the auxiliary extender down to a more standardised 54mm thread.  This adapter has a 72mm male thread on the telescope side and drops the aperture down to M54 female so that common accessories can be used. No other manufacturer that I know of uses M72 other than Takahashi so we need a way to convert from the Takahashi M72 to an "ordinary" system!  The CA35 adapter is what does this and it also adds another 25mm to the imaging train.  This adapter is more expensive at about £60.  I told you these adapters were expensive !!!!!

NOTE:  I already owned the above adapters a decade before I bought the QHY268C since most FSQ85 users will own them for other imaging requirements.  However, they are additional to the purchase of the scope itself.  Takahashi ownership is an expensive business!

Connecting To The Back Of The CA35 With The ZWO Filter Drawer (and rationale for going this route)

The adapters I explained in the paragraphs above are quite "standard" in the context of setting up a FSQ85 all-threaded imaging system.  I now needed to work out how to connect the QHYOAG-M to the CA35 with a filter drawer.  I also still needed to make up some distance in the imaging train to get to the 200mm or so needed to get the cameras to focus because even with the above adapters it is still short of the required distance to get the camera to focus.


ZWO_Filter drawer male side
ZWO M54 Male side - bottom view

ZWO_Filter drawer female side
ZWO M54 Female side with M54>M48 adapter on the table

ZWO_Filter drawer in the middle
Top view of the filter drawer

ZWO M54 Filter drawer
Filter drawer as supplied in packet

I need a way to be able to insert 2" filters into the imaging train, as discussed above.  For sure, I'd always image in OSC with either a LDAS LP filter or a UV/IR cut filter in front of the camera.  But I might want to image with a filter such as the Optolong L-Extreme filter too.  This means whatever filter I use must be readily changeable when at the scope.  QHY supply a spacer with the QHY268C that has a thread for a 2" filter and this can be used to space out the the OAG on the camera-side as discussed in my previous thread.  The problem with that method is that it makes the filter difficult to get access to and change, not impossible but tricky and awkward, certainly so at night when, for whaever reason, you change your mind and need to image soemthing different!   Another way is I could use a filter wheel between the OAG and the camera but I don't want to spend another £300 on this and have another device needing power/USB.  So my thoughts were to use a filter drawer in front of the OAG. 

ZWO make a filter drawer (£75) with a 2" compartment for filters and with M54 fitting scope and camera side.  I need the filter drawer to have two male M54 threads on either side ideally ideally so that it can mount with the QHY OAG mounting plate and also the CA35 - both of which expose a female M54 thread.  However, the ZWO is made with male M54 on one side and female M54 on the other, so I need to change the gender of one side 🙄.    Using a filter drawer like this in front of the OAG was a gamble in case I could not pick up guide stars through the filter.  More on that later.....

The filter drawer has a slide-in compartment with a strong magnetic catch to keep it secure.  The drawer is also provided with a very useful accessory; a M54 male step-down adapter to M48 female.  As it happens, the Williams Optics Redcat also has a male M48 on which to mount a camera. So this makes a perfect system and I can kill two birds with one stone.

1.  If I mount the ZWO filter drawer with the M54 female side facing the telescope, then I can use an M54 male to M54 male gender change adapter (Takahashi OU031) to connect the female side of the filter drawer to the M54 female thread of the camera side of the CA35 Takahashi adapter.  The male side of the filter drawer then screws directly into the OAG.

2. If I want to mount the camera to the Redcat I remove the camera after the M54-M54 male-male adapter, install the screw-in ZWO supplied M54>M48F adapter and I can then mount the whole OAG/Camera/Filter drawer assembly to the Redcat :)  Additionally with this filter drawer it will connect onto my Samyang/Rokinon 135mm lens that I have modified slightly with this adapter.

The ZWO filter drawer also adds 24mm of back focus to get us to our goal of 200mm or so to get the cameras focused.


OU031 Takahashi Adapter
Takahashi OU031 Male to male M54 adapter

OU031 Takahashi Adapter packet
Takahashi Adapter in its packaging

The Takahashi OU031 adapter above joins the female side of the ZWO filter drawer to the female side of the CA35.  This simple adapter costs an astonishing £62 !  Other than make them myself I see little alternative other than to pay this exorbitant price.

The male (i.e. camera) side of the filter drawer screws into the M54 female telescope side of the OAG.

And there, we have a completely threaded mounting solution with QHY268C and the guidecam focused at the correct distance!

Will The Guidecam Focus ?

Clearly, the mechanism described has the filter drawer out in front of the OAG and the guidecam.  In other words, the guidecam must look through the filter to find a guide star.  This was a concern when I set up this arrangement, would guide stars show through? However, I can confirm that with a 2" LDAS LP filter installed the guidecam picked up stars without any problem at all.  This will be by far my most predominant use-case for my QHY268C - 95% of the time I will be doing broadband.

Now, that said, I am interested in acquiring an Optolong L-extreme filter which only allows through some very specific narrowband emission lines.  It will remain to be seen if a guidestar can work with this filter drawer arrangement and if a guidestar can be seen through the L-Extreme filter.  If not, I will need to have a rethink and see if the L-extreme can be installed behind the OAG in some way on the occasions when I may want to capture narrowband through with this camera.

Update: 12 October 2020

The weather in the UK has been very cloudy and wet and since I authored this page and since then I have only had only snatched 15 minutes of clear sky time here and there; imaging in the UK is exceptionally challenging!  However, on 11th October I managed to build a picture from 47 subs.  Please see my first light post to read about this.  A sneak peek on the image below :)


Complete_OSC_NAN_smaller
QHY268C First Light

Update 2: 16 October 2020

I had an unexpected clear night, although the seeing was bad, and managed to get 55 x 4 minute subs of IC1396 - Elephant Trunk Nebula.

I think the camera is a good one and exciting times ahead with it hopefully :)


The Elephant Trunk Nebula
QHY268C and IC1396

Clear skies,  Steve


Unboxing, Impressions And Initial Setup Of QHY268C and OAG-M

Introduction And Rationale For Purchase


QHY268C on FSQ85
QHY268C on Takahashi FSQ85. Note the totem pole of adapters to the right of the QHYOAG-M in order to get a screw fit onto the FSQ85 focuser

I am already a very happy owner and user of two CCD mono cameras and associated filter wheels; an Atik 460 CCD with EFW2 and a Moravian Instruments G2-8300 CCD camera.  I have been very pleased with the performance of both, I enjoy using them and will continue to do so.  I have connected my Moravian CCD for use exclusively on my Samyang 135mm lens and it is semi-permanently attached to it.  I have my Atik460 semi-permanently attached to my TEC140 scope.   I do not want to disturb these two hardware arrangements.  However, this leaves me without a camera for my excellent Takahashi FSQ85.  So with this in mind I needed to acquire a third, cooled, astro-imaging camera.

I considered buying a QSI683 CCD or maybe an Atik 8300 chip CCD camera.  However, I think the era of CCD in amateur astrophotography is coming to an end and CMOS appears to be the strategic direction with the development of bigger and more sensitive imaging chips.  I do not want to make an unwise investment in another CCD camera so I started my investigations into the popular CMOS based cameras from the Chinese QHY and ZWO brands.  After reading some superb reviews about how incredibly good the current generation One Shot Colour (OSC) CMOS cameras are nowadays, with their 16 bit depth, high resolution and high QE efficiency allied with very low read noise and zero amp glow I decided to take the plunge and order the QHY268C camera.   This camera offers incredible bang for the buck being based on a large APS-C sized, 26 million pixel sensor, the Sony IMX571.  This is the same sensor as that used in the superb Fujifilm XT-3 mirrorless camera. 

We are plagued with cloudy skies in the UK at the best of times and I do not want to invest in another mono camera with filters at this point.  I have so many half finished images with data sets missing a colour or two that it is sometimes taking me several years to finish an image, which is most frustrating as I am sure many of you know only too well.  You get partly through the run, with say the LRB filters done then the cloud rolls in for three weeks and at the end of that time the object has set behind the houses or trees for that particular year!   I want to be able to take images with just a light pollution filter and get something in the can in an evening or two when there is a clear period. This is my rationale for buying a OSC camera.  

At the time of this writing - September 2020 - I am aware that QHY and ZWO are working on APC-C sized mono cameras too and I may consider one of those in the future.  However, for now I wanted a OSC for this purchase. The resolution of the current generation OSC sensors is so high that even with their Bayer matrix, they are capable of very good narrowband imaging with the multiple wavelength narrowband filters from Otolong and others, for instance the L-Extreme filter. 

I understand and accept that ultimately, nothing will beat a mono sensor and the associated filters.  By going mono you are dedicating the entire sensor's resolution and pixels to that one wavelength.  So with mono you will always, ultimately, gain a better resolution and S/N ratio.  Accepted.  However, that is in an ideal world.  I am very much removed from that ideal world nirvana.  Firstly, in the UK, I live in a cloud infested country underneath the junction of major Atlantic, European and Polar weather systems converging above with the jet stream running straight above me. Consequently I sometimes struggle to get two clear nights of imaging in a month.  It can often be much worse than that even and I have known winter seasons that were complete write-offs with only two or three nights across the entire season. As I alluded to before, collecting multiple filters worth of data to complete a broadband or composite image is simply not possible in reasonable timescales if a deep integration is needed.  In the past we would have to suffer this because the alternative, OSC, simply was nowhere near as good as mono.  That is no longer the case with the latest generation of OSC sensors from QHY and ZWO.  Secondly, with my skies and circumstances, I am never going to be able to "compete" with some of you guys who live in climates where more clear skies are available to spend the time on mono filter images.    I simply do not have that clear sky time and will never have the data quality to be an APOD contender.  I accept my limitations but still love the hobby of astrophotography for its own sake, not to be a champion.  This makes the latest generation of OSC cameras very attractive to me.

I bought this camera from Bern at Modern Astronomy together with the QHYOAG-M.  I want to off-axis guide the FSQ85 which this camera will be mostly connected to.  However, I also sometimes want to mount it on my Williams Optics Redcat 51 with the OAG, depending on the object target.  Both setups offer a superb, wide field with this camera.

The camera costs a princely £2049 with the OAG another £199.  Not insignificant sums by any standards. 

Receiving The Camera




















The camera is shipped in a rather nice outer QHY cardboard box which is very sturdy.  The lid is shrink wrapped to protect it.  The box was immaculate, undamaged and had been protected in transit from Bern by being packed in an outer box with lots of packing.  I always keep the boxes of my stuff in case I ever decide to sell the stuff in the future as it makes it more desirably to a lot of folks.

The camera itself is protected in thick, Styrofoam moulded to its shape.  Underneath this tray holding the Styrofoam with the camera is a lower area with four boxes that include the spacers, power supply, power cable, cigarette light style power cable desiccant/holder.  It is all very neatly packaged.  I have no need of the power cable or supply and made my own power cable with a 2.5mm plug to connect into the 12v power distribution bar on my mount.

The camera is a solid, robustly built, quality item with a nice hefty feel to it without being overtly heavy.  The sensor seems huge compared to my other astronomy cameras!  Gone are the days with the tiny sensors!

So far, so good.  I'm impressed (and remain so, but more about that later ;) ).

Connecting The OAG to the Camera - Attempt 1

I want to set up my QHY268C camera - a OSC as discussed - with the OAG, a QHYAG-M which presents an M54 thread. No need for a filter wheel in a colour camera (more on that later).

It took me a while to work out how to connect the OAG camera side to the tilt plate adapter that the camera body is held onto with three knurled thumb screws.  On the telescope side I am (for now) using a M54 to 2" nosepiece adapter.  I then installed my puck style ASI174mm camera into the OAG, as indicated in the QHY OAG diagram, since the diagram implies that this arrangement will work.


QHY268C and OAG-M

Measurement of OAG distance

Measurement of QHY268C distance

I then tried to get the focus set up on my Takahashi FSQ85 to the main imaging camera and the guide camera.  This telescope has quite a long backfocus distance from the rear of the focuser housing to the point of focus, about 195mm, that I will discuss in another post.  However, with the the necessary [expensive] Takahashi adapters I got the main camera into focus using Sharpcap and my Lakeside autofocus.  Cool.  Then, firing up PhD2 I tried to focus the guidecam in the OAG.  Miles out of focus and after much cursing and fiddling with gain, offset and exposure of the ASI174M I measured the distance from the sensor of the guidecam compared to the distance of the main QHY268c imaging camera and as can be seen in the photos above, they are radically different.  The main imaging camera is about 42mm from the front of the nosepiece whereas the guidecam is the best part of 100mm - 58mm in difference!!!!!!  No wonder I cannot focus the guidecam, it is much too far from the focus point of the FSQ85!

Connecting The OAG to the Camera - Attempt 2

It had been a long day with this, work, the kids and other things.  After sleeping on it, after some head scratching and upon further thought, the distances are different  of course because the ASI174M is a "puck" style camera, its imaging chip is being held above the top of the OAG.  Clearly I need to use a 1.25' "bullet" style guider where the chip is right at the front and can be inserted deep into the focuser of the OAG-M, thereby significantly shortening the distance from the guidecam chip to the FSQ85s focal plane.

As it happens, I have a ASI120MM mini guidecam on another rig so that I could test this theory.  So I installed this and I could start to see the blurred outline of the trees and houses that I was using to perform this  daytime test of focus of the QHY268C and the guidecam.  So with this bullet cam I was nearly in focus but not quite - it needed to be a bit nearer to focus still.  So using some of the spacers provided with the QHY268C and a bit of experimentation, I found I needed 13mm of extensions to "pad" out the OAG camera side to the camera.  Upon thinking about it, this makes sense because this padding would be where a filter wheel would be if one was installed!  I also needed to buy some 35mm M3 screws off of Ebay since the ones provided with the camera are not long enough.  You need six of them.  They cost pennies.


QHY268C ASI120MM
With bullet style guidecam and spacers

QHY268C Spacers Callipers
Thickness of spacers

As soon as I did this I could get the two cameras simultaneously focused.  Note however, that if you move the adjustable pickoff prism in the OAG, you will make the guidecam either nearer or further away (from the FSQ focal point) and may need to refocus the guidecam.  So it is important to get the pick-off prism adjusted so that it just clears the line of sight of the main camera's imaging chip.  Otherwise you will get artefacts on your light frames. Flats will take care of this of course but it is better not to have the prism in the light path to the main imaging chip in the first place.


QHY268C FSQ85
Main QHY268C in focus

QHY268C Guidecam
Guide Camera in Focus

As is normally the case when wanting to test new gear, the weather is not cooperating at all.  I managed to get one 300s light frame in before it clouded over on the evening of Friday 25th September 2020 :) We've had no clear skies since then🙄.

It is an impressive start, all I did was unbayer the image in Pixinsight and then stretch it and boost the colours a bit.  Nothing else.


NAN_1st_300s_1x1
First light of QHY268C and Takahashi FSQ85

After quite a bit of fiddling about that took several hours I now have the main camera and the guide cameras in simultaneous focus on my FSQ85.  

I look forward to good things from this combination and will update my site with my latest thoughts.  So far, very early in my career with this camera, I am very impressed!

N.B.  These views of my QHY268C camera and OAG are mine.  No one paid me any money or offered me any discounts or services on anything astronomy or otherwise nor did they request I write this article.  I bought everything I use on my website with my own money and offer my thoughts, ideas and opinions to help others because I enjoy doing so, not for material or financial gain for myself.

Meade_TEC_SBS_Corrector

Meade 14" ACF

I bought the 14" ACF SCT Optical Tube Assembly (OTA) telescope in excellent condition in April 2019 second hand.  These ACF (Advanced Coma Free) SCT scopes from Meade have an excellent flat field and my intention upon purchasing this scope was to use it for lunar and planetary visual work and also for some astrophotography.


Meade_TEC_SBS_Corrector
Meade 14" ACF

The SCT telescopes increase in size and weight is almost exponential with their increasing aperture.  This scope is VERY heavy at almost 27kg and I had it mounted side-by-side with my [also heavy] TEC140.  I needed almost 40kg of weights to balance this combination.  It was very close to the MESU200's maximum weight carrying ability and caused the mount to shiver for a few moments after any physical touch of the mounted telescopes.

I originally intended a three scope combination with the Meade 14", TEC140 and my FSQ85, the latter two attached to the cameras since I only use these for astrophotography.  However, no matter what I tried I could never get this combination to balance in all orientations.  If I got it balanced in the parked position then they'd be unbalanced in the "point east

position".  Get it right pointing east and the meridian flip would fail.  It was like a game of whack-a-mole and a balance problem would repeatedly keep popping up no matter how I adjusted the scopes on their dovetails and in their saddle.  In the end I abandoned mounting the FSQ85 and did a dual rig side-by-side with the Meade and the TEC140.  Even this was never perfectly balanced and caused the MESUs friction drive to give way on some occasions and I'd awake in the morning following an all-night imaging run with the scopes pointing up at the zenith.  Also, because the scopes were so heavy it was a challenge for the MESU to hold them perfectly steady.

I fitted the Meade with a Moonlite Crayford focuser and equipped it with motor focus.  With such a long focal length and physical touching of the scope to focus it causes the observed object to wobble for a few seconds and makes focusing a challenge without motorfocus.  The fitting of the motorfocus massively assists the usability of the scope.  Indeed, I'd suggest just using the mirror focuser would be a very big ask when trying to fine focus.


Meade Side by Side with TEC140


Bottom of Meade 14"ACF


Side of Meade 14" ACF


Meade 14" ACF Corrector


Meade 14"ACF with Moonlite Crayford motor focus


Side View

I sued the scope a lot on The Moon and for some deep sky observations.  It excelled on objects such as M27 and M13 and other small objects needing a significant focal length.

However, my overall ownership was a bit of a disappointment and this is absolutely in no way a fault of this magnificent telescope.  It is a result of my own aperture fever.  Such a telescope in a Bortle 5 suburban sky is always going to be significantly handicapped and this indeed proved the case here.  So much so in fact that I hardly even used it on faint galaxies because such objects are drowned out by the light pollution.  Jupiter and Saturn were very poorly placed for observers at my latitude (53N) during my ownership so I never got chance to use it on those.  In fact, I found my Celestron C925 showed as good a view in my skies.  For these reasons, I sold the telescope, minus the focuser in May 2020, after a year of ownership.   In the end I sold it to someone from Derbyshire Peak District who has dark skies. I was sad to see it go because in the right skies it will be magnificent.


Meade_TEC_SBS_Corrector

Meade 14" ACF

I bought the 14" ACF SCT Optical Tube Assembly (OTA) telescope in excellent condition in April 2019 second hand.  These ACF (Advanced Coma Free) SCT scopes from Meade have an excellent flat field and my intention upon purchasing this scope was to use it for lunar and planetary visual work and also for some astrophotography.


Meade_TEC_SBS_Corrector
Meade 14" ACF

The SCT telescopes increase in size and weight is almost exponential with their increasing aperture.  This scope is VERY heavy at almost 27kg and I had it mounted side-by-side with my [also heavy] TEC140.  I needed almost 40kg of weights to balance this combination.  It was very close to the MESU200's maximum weight carrying ability and caused the mount to shiver for a few moments after any physical touch of the mounted telescopes.

I originally intended a three scope combination with the Meade 14", TEC140 and my FSQ85, the latter two attached to the cameras since I only use these for astrophotography.  However, no matter what I tried I could never get this combination to balance in all orientations.  If I got it balanced in the parked position then they'd be unbalanced in the "point east

position".  Get it right pointing east and the meridian flip would fail.  It was like a game of whack-a-mole and a balance problem would repeatedly keep popping up no matter how I adjusted the scopes on their dovetails and in their saddle.  In the end I abandoned mounting the FSQ85 and did a dual rig side-by-side with the Meade and the TEC140.  Even this was never perfectly balanced and caused the MESUs friction drive to give way on some occasions and I'd awake in the morning following an all-night imaging run with the scopes pointing up at the zenith.  Also, because the scopes were so heavy it was a challenge for the MESU to hold them perfectly steady.

I fitted the Meade with a Moonlite Crayford focuser and equipped it with motor focus.  With such a long focal length and physical touching of the scope to focus it causes the observed object to wobble for a few seconds and makes focusing a challenge without motorfocus.  The fitting of the motorfocus massively assists the usability of the scope.  Indeed, I'd suggest just using the mirror focuser would be a very big ask when trying to fine focus.


Meade Side by Side with TEC140


Bottom of Meade 14"ACF


Side of Meade 14" ACF


Meade 14" ACF Corrector


Meade 14"ACF with Moonlite Crayford motor focus


Side View

I sued the scope a lot on The Moon and for some deep sky observations.  It excelled on objects such as M27 and M13 and other small objects needing a significant focal length.

However, my overall ownership was a bit of a disappointment and this is absolutely in no way a fault of this magnificent telescope.  It is a result of my own aperture fever.  Such a telescope in a Bortle 5 suburban sky is always going to be significantly handicapped and this indeed proved the case here.  So much so in fact that I hardly even used it on faint galaxies because such objects are drowned out by the light pollution.  Jupiter and Saturn were very poorly placed for observers at my latitude (53N) during my ownership so I never got chance to use it on those.  In fact, I found my Celestron C925 showed as good a view in my skies.  For these reasons, I sold the telescope, minus the focuser in May 2020, after a year of ownership.   In the end I sold it to someone from Derbyshire Peak District who has dark skies. I was sad to see it go because in the right skies it will be magnificent.


Howie Glatter Laser Collimator

In order to get the best from your observing and imaging sessions, your reflecting telescope needs to be properly collimated.  In other words, the optical axis of the telescope must be optimised to reflect the light optimally.  Newtonian and Ritchey- Chretien design scopes do not deliver a crisp and sharp image unless they are properly collimated.  A laser collimator is a device that can aid in getting the telescope properly collimated.

I want to emphasise that I am not in any way paid in money or kind to write these words.  I do this for the love of it and to help others and I have no connection whatsoever to the maker of these collimators.

Sadly, Howie Glatter himself passed away in 2016. He was a very kind man and was incredibly friendly, knowledgable and approachable.  There was almost nothing he didn't know regarding the subject of collimation of telescopes!  His company was taken over by Starlight Instruments.  My review in the video below was made in 2013 and my example was made by the late Howie himself.  However, the pedigree of Starlight Instruments, famous because of their focusers, would imply that the exactitude of Howie's methods are continued.

Rather than me type a novel here, please review the video.  I think you will see that I am most impressed with my example!

Clear skies and happy collimating! :)

https://www.youtube.com/watch?v=I4YPT1aRf2U


Further Experience with Takahashi FSQ85 Baby Q

I have had the scope for three weeks now and have used it three times. That's good going in the UK in case you possibly thought that's bad; it's not uncommon to wait for six weeks for a first light in our cloudy climate!  Anyway, leaving aside the usual British moans about our weather......

The FSQ is so easy to use.  Just point it, focus and forget.  I am using Baader LRGB filters in 1.25" guise in an Atik EFW2 filter wheel.  These filters are stated to be parfocal.  However, with my Skywatcher ED80 telescope I found they were not.  The focus wandered slightly between the filters.  I normally focus on the Luminance channel first.  I then grab LRGB in that order.  But by the time I got to the blue filter I found stars were becoming bloated, not massively - but enough to take the edge off the picture.  This problem is definitely not an issue with the ED80 stock focuser - I could adjust that sufficiently to make it rock solid -  but is more attributed to the differing light wavelengths coming to a minutely different focus with the ED80 primary objective, blue is always affected worse.  This is hardly surprising at the ED80 price point and indeed, the ED80 is an excellent telescope for its price.  When using the FSQ though the focus is perfect on all LRGB filters and is as perfect on all four corners of the image.  It just makes the scope so easy to use.  I sincerely hope this is also the case when I get some Baader narrowband filters as well.  However. considering the FSQ is ten times the cost of the ED80 is it ten times better?  Of course not.  That is not the way of things - it is diminishing returns at this end of the market as is the case with any other premium product.  You pay a massive amount more to make it 20% better.

The FSQ-85 focuser is heavy and robust.  However, a slight word of caution here that knocks a mark off the score for the FSQ-85.  I have found that with my filter wheel and camera attached (EFW2+Atik460 = just over 1kg so hardly that heavy) I find that I need to have some focus knob lock applied or else the focuser can start to very slowly slip when pointed at over 50 degrees or so above the horizon.  This came as a bit of a surprise to me since I have read some web articles that state the focus lock can be fully undone and the focuser does not slip even when pointed vertically.  This is not my finding; I need some focuser lock applied to "brake" the slip and can then use the fine focuser.  That makes me give the scope 9/10.  Otherwise it would have got a perfect 10/10.  I penalise it a full mark since the focuser action is a critical part of using a scope and at this price point I should not be expected to start shelling out yet more money for after market focusers or fiddling with tightening screws etc.  This is a Rolls-Royce scope; you don't buy a Roller and expect to be under the hood tinkering on day 1.  I need to do some further research into this.  Maybe the focuser can be "tightened" perhaps..... Or maybe my expectations are unrealistic and this is the whole point of having the focus lock.  To be fair the use of the lock screw is pretty intuitive and easy.  Had it not been I would have sent the scope back (EDIT 2016 - I now use a Lakeside autofocus system that prevents any wander of the focus)

What is very commendable about the FSQ is the accuracy of the Camera Angle adjuster and focuser working together.  So, when I achieve precise focus and then need to turn the CAA to frame the subject (something that I will be doing all the time) the focus does not shift even a fraction.  I checked it out by slewing the scope to a bright star and putting on the Bahtinov mask after so adjusting the CAA after previous focus - the focus had not moved at all.  That shows how accurately the scope and its bits are made.

I have used the FSQ on two objects so far, in both cases at native focal length - I have yet to use it with the reducer even though I bought the reducer with the scope.  I grabbed further data on M33 Triangulum galaxy to add to the image on my previous post and I also grabbed RGB on the Double Cluster.

M33_Nov_2013

This image of M33 in Triangulum (lower quality here as a jpeg) has two hours of Luminance and 90 minutes each of RGB. The Luminance was 1x1 binned and the RGB was 2x2.  The data was captured on the evenings of 21 and 25 November 2013 from my back yard (semi light polluted).  I also should really have been using my IDAS Hutech Light pollution filter! All processing was in Pixinsight.  The image needs more data to really let the spiral arms and the HII regions jump out.  It could use some Ha as well.  Nevertheless, it is coming along nicely I think.  The two data sets are closely aligned and that will allow me to grab a whole lot more data.  Next time it is clear I will grab a lot more luminance and Red data.  Indeed,  I might push the subs out to 15 minutes.  What stops me doing that normally is that Nottingham is under the flight path for US West Coast flights from Heathrow that tend to plague my exposures!  It hurts throwing away otherwise perfect 15 minute subs!  However, I have recently discovered that Pixinsight's Windsorised Sigma clipping routines are extremely effective at removing plane and satellite trails, especially if I use dithering during capture.

The important thing to note is the stars are nice and round in the corners so the scope is performing very well!  You can see this image at higher resolution here.

Next up is the Double Cluster in Perseus.  This data was captured on 4th December 2013, again from my back yard.  This time though I used the IDAS LP filter and this has reduced light pollution light splatter very effectively.


The Double Cluster
The Double Cluster

Star field pictures show errors in an optical system all too readily and I am very pleased the FSQ came through this test very well, despite very mediocre seeing on the night.  Here are 30 minutes per RGB channel at 5 minutes exposures, binned 1x1.  Higher resolution of this image is here. There is no luminance here at all.  Also, no flats here since I mistakenly captured the flats at 2x2 binning as I normally bin 2x2 on RGB!  Doh... Oh well, it still came out quite well with Pixinsight's DBE tool to remove the vignetting.

So, to sum up, I am very pleased with the scope so far.  It is optically wonderful.  It looks the part and I have great pride in owning it.  The build quality is superb.  The focuser is good and robust but has slight slippage that has taken the edge off a tiny, weeny bit.

Would I buy again?  Absolutely!  This is scope for life and look forward to doing some great things with it.  I might even buy a FSQ-106 to go with it as well ;)

Next blog entries will be how I connect all the bits together to connect to my Atik EFW2 at both native and reduced.  Another blog entry will be about how I mounted the scope to my NEQ6 and guide-scope.


FSQ85

My Takahashi FSQ85 "Baby Q"

I bought my Takahashi FSQ-85EDX telescope from Ian King Imaging in November 2013 and bought it with the 0.73 reducer and numerous Takahashi adapters.  I have not as yet used it reduced, only at the native F5.3.  I am very impressed with the scope so far.  It weighs only 4kg but feels so much more than that.  The scope is a thing of beauty with impeccable paintwork and build quality.  This is truly a scope to last a lifetime if cared for.

I went around the mental "shall I buy a 85 or 106" loop a million times.  However, I already have a TEC 140 telescope to give me a smaller (or zoomed in) image scale for smaller objects like M81, M87 etc and the Abell galaxy clusters.  I felt the FSQ-85 gave me better options for wide-field imaging of large targets like M31, M33, North American Nebula, Rosette Nebula etc.


FSQ85
FSQ85 with Guide Scope on NEQ6

My FSQ-85 rig consists of a Skywatcher ST80 guide-scope with a QHY5 guide-camera.  The whole shebang is mounted by ADM dovetails/bars/saddle onto a Skywatcher NEQ6 mount and I control it all via ASCOM/EQmod from my Dell D630 latitude laptop.

Here is a picture I did of M33 with 75 minutes of Luminance, binned at 1x1 and 20 mins each of RGB binned at 2x2.  All this done on an Atik 460 at -21C.  The seeing was terrible, the moon was rising and I was dodging clouds!  To say the UK climate is challenging for Astro-Photography with our milky white skies and constant cloud is the understatement of the century!

M33_Nov_2013

The image really needs more data in the colour channels and ideally some Ha as well to bring out some of the HII regions.  But not too shabby at all for a first light I reckon under the circumstances. All four corners are nicely round.

All in all I am impressed.  I intend to do some videos of how I mounted this scope so watch out for those.  I also will do some articles on how the camera connects to the scope in both reduced and native guises with the different Takahashi adapters.


Privacy Preference Center